Specifications

Conductor Material Copper
Packaging As per client requirement
Use in Thermocouple

Benefits :

  • Generates measurable electrical energy with dissimilar conductors
  • Enhanced performance in high operating temperature environments
  • Color coded insulation and jacket materials for easy identification


Features :

  • Meets ANSI/IEC Type E/J/K/T/EX/JX/KX/TX standards
  • Multiple alloy options for measuring electrical readings
  • Additional constructions available upon request


Details :

  • Limits of error per ANSI MC96.1-1982. Limits shown do not include system or installation error. Percentages refer to the temperature being measured.
  • The Temperature Range and Limits of Error are for standard grade thermocouples. Reference ANSI MC96.1-1982 for special grade thermocouples.
  • The Temperature Ranges for type E, J, K and T thermocouple wires listed above pertain to 20 AWG wire.
  • ANSI = American National Standards Institute
  • Additional constructions available upon request.

Yes! I am interested


Technical Data

ANSI Symbol Temperature Range (oC) (conductor only) Limits of Error Standard (oC) Jacket Color Insulation Color Code Conductor Identification
Positive
( + )
Negative
( - )
Positive
( + )
Negative
( - )
E 0 to 340
340 to 540
±1.7oC
±0.50%
Brown Purple Red Chromel®
Non-magnetic
Constantan
Silver Color
J 0 to 293
293 to 480
±2.2oC
±0.75%
Brown White Red Iron
Magnetic
Constantan
Non-magnetic
K 0 to 340
340 to 540
±1.7oC
±0.50%
Brown Yellow Red Chromel®
Non-magnetic
Alumel®
Magnetic
T 0 to 340
340 to 540
±1.7oC
±0.50%
Brown Blue Red Copper
Copper Color
Constantan
Non-magnetic
EX 0 to 200 ±1.7oC Purple Purple Red Chromel® Constantan
JX 0 to 200 ±2.2oC Black White Red Iron Constantan
KX 0 to 200 ±2.2oC Yellow Yellow Red Chromel® Alumel®
TX 0 to 200 ±1.0oC Blue Blue Red Copper Constantan
Thermocouple Identification and Limits of Error – Reference Junction 0°C * 