Business Type Supplier, Retailer, Wholesaler
Use In Electrical Instruments
Min. Order Quantity 100 Piece
Packaging As per client requirement

Preferred Buyer From

Location Anywhere in India

Provides two types of Masters, a Master Unit with screw-less clamp terminal blocks and a Master Unit for M12 Smartclick connectors, as IO-Link compliant devices and Sensors for connecting to the screw-less clamp terminals or to the M12 connector terminals that support each Master.

Details :

  • Downtime can be reduced.
  • Notifies you of faulty parts and such phenomena in the Sensor in real time.
  • The frequency of sudden failure can be decreased.
  • Notifies you of objects being too far or too close.
  • The efficiency of changeover can be improved.
  • The batch check for individual sensor IDs significantly decreases commissioning time.
  • Standard Sensor for detecting ferrous metals.

Yes! I am interested


Specification

Item Size M12 M18 M30
Shielded Shielded
Model E2E-X3B4-IL[] E2E-X7B4-IL[] E2E-X10B4-IL[]
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance *1 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal
(The sensing distance decreases with non-ferrous metal. Refer to Engineering
Data on Catalog.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *2 1 kHz 0.5 kHz 0.4 kHz
Power supply voltage 10 to 30 VDC (including 10% ripple (p-p))
Current consumption 20 mA max.
Control output Load current 100 mA max.
Residual voltage 2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators *1 In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability
indicator (green, lit)
In the IO-Link mode: Operation indicator (orange, lit) and communication indicator
(green, blinking at 1 s intervals)
Operation mode PNP NO/NC switching type (Factory setting: NO)
Refer to the timing charts under I/O Circuit Diagrams on Catalog for details.
Protection circuits Power supply reverse polarity protection, output reverse polarity protection, surge
suppressor, and output short-circuit protection
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant *3
Connection method Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
(Standard cable length: 0.3 m)
Materials Case Nickel-plated brass
Sensing surface PBT
Clamping nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Main IO-Link functions Operation mode switching between NO and NC, self diagnosis enabling, excessive
proximity judgment distance selecting, timer function of the control output and
timer time selecting, instability output (IO-Link mode) ON delay timer time selecting
function, monitor output, operating hours read-out, and initial reset
Communication
specifications
IO-Link
specification
Ver 1.1
Baud rate -IL3: COM3 (230.4 kbps), -IL2: COM2 (38.4 kbps)
Data length PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)
Minimum cycle
time
-IL3 (COM3): 1 ms, -IL2 (COM2): 2.3 ms
Accessories Instruction manual